EKCO.LN2

PrintE-mail

EKCO_LN2_aranzacja

EKCO.LN2 electric central heating flow boilers are designed for wet central heating installations and hot water cylinders. It's equipped with an expansion vessel (Capacity: 6 litres) and the differential pressure valve (Bypass). They can either operate as an independent source of heat or cooperate with other boilers. The application of the proper control system ensures high heat comfort, nearly maintenance free work as well as the possibility of individual setting adjustment. The quick system reaction to the changes of temperature together with the automatic 6-stage power modulation ensures the maximum efficiency in the power consumption.

Download

 

Features:

  • Panel control - electronic control board enures regulation of water temperature in central heating installation between 20oC do 85oC
  • Power board - consists of electronic and semiconductor elements to ensure noisless and failure-free performance.
  • Safety temperature limiter - cuts off the power in case of boiler failure. Protects heating box and electronic elements against failure.
  • Differential pressure reliew  valve (Bypass) It allows the system to keep minimal flow of medium through the boiler and reduces a noises in installation during the thermostatic valves closing.
  • Magnetic filter F-MAG 3/4" - due to special construction ensures double filtration effect: mechanical and
    magnetic. The magnetic filter protects the boiler measuring elements (eg. flow sensor) from ferromagnetic molecules which appear as the effect of
    the interference with and corrosion of central heating installation.

  • Circulation pump
  • Safety valve- 0,3MPa
  • Automatic vent
  • Pressure sensor

EKCO_LN2_budowa_wewnetrzna_kopia

EKCO_LN2_anglia

Optional equipment

 

Zawor_silownik Three way valve allows cooperating with a  hot water cylinder.
The temp. in cylinder can be set on front panel if a WE-019/01 temperature sensor is applied. The boiler can also co-operate with a cylinder equipped with a thermostat.

 

Auraton Temperature programmer
Temperature programmer (for example Auraton2005) allows control of boiler operation according to user's requirements

.

Technical data

 Rated power

kW

4

6

8

4

6

8

 Rated voltage


230V~

400V 3N~

 Fuse rated current

A

20

32

40

10

16

 Min. connecting wires section

mm2

3x2,5

3x4

3x6

5x1

5x1,5

Approximate heating area*

m2

30-50

40-70

60-100

30-50

40-70

60-100

 

Rated power

kW

12

15

18

21

24

Rated voltage


400V 3N~

Fuse rated current

A

20

25

32

40

Min. connecting wires section

mm2

5x2,5

5x4

5x6

Approximate heating area*

m2

100-140

130-180

150-220

180-250

220-300

*While calculating demand for thermal energy, a number of factors should be taken into consideration:

- building cubature
- value of heat transfer through walls, windows and ceilings
- level of room ventilation
- heat accumulation

All technical data is based on standards of Central European countries. However, Kospel S.A. is fully flexible to adjust its appliances to other standards.


 